SC440L MT RETARDER LIQUID
Product Description
1.Retarder helps extend the thickeningƟ me of cement slurry in order to keep it pumpable, which ensures sufficient pumping time for a safe cementing project.
2.Applicable for low-to-moderate temperature system, used below 90℃ (194℉, BHCT).
3.Mixed with water when applied, and water quality is not required.
4.When curing temperature is lower than bottom hole circulating temperature, strength of set cement at top may be affected.
5.The dosage of SC440L increases significantly when applied above temperature of 95℃, strength of set cement at top may be affected.
Specifications
Appearance |
Density,g/cm3 |
Water-Solubility |
Colorless liquid |
1.10±0.05 |
Soluble |
Cenment Slurry Prescription
Cement Slurry Density |
Recommended Dosage |
1.90±0.01g/cm3 |
Adjust dosage according to cement type |
Cement Slurry Performance
Item |
Test condition |
Technical Indicator |
Initial consistency, Bc |
80℃/45min, 46.5mPa |
≤30 |
40-100Bc thickening time, min |
≤40 |
|
Thickening time adjustability |
Adjustable |
|
Thickening curve |
Normal |
|
Free fluid, % |
80℃, Atmospheric Pressure |
≤1.4 |
Compressive strength for 24h, mPa |
80℃, 20.7mPa |
≥14 |
Composition: API Class G(HSR) 700g, mixed water 308g(including liquid additives); defoamer 1.4g (0.2%); SC440L |
||
Remarks: The dosage of SC440L is determined under te precondition of adjusting the thickening time range of cement slurry from 130-270 min at 80℃ |
Standard Packaging and Storage
1.Packed in 25kg, 200L and 5 US gallon plastic barrels. Customized packages are also available.
2.Customized packages are also available. Once expired, it shall be tested before use.
Package
25KG/BAG or as you request.
Storage
Store at a ventilated, dry place.
Executive Standard
International Standard.