page banner

AF870 Fluid Loss Additive

AF870 Fluid Loss Additive


  • Product Name: AF870 Fluid Loss Additive
  • Other Names: /
  • Category: Fine Chemical - Oil Field Chemical
  • CAS No.: /
  • EINECS: /
  • Appearance: Colorless or faint yellow liquid
  • Molecular Formula: /
  • Brand Name: Colorcom
  • Shelf Life: 2 Years
  • Place of Origin: Zhejiang, China.
  • Product Detail

    Product Tags

    Product Description

    1.AF870 fluid loss additive is a synthetic polymer which is capable of effectively reducing water loss filtering from the slurry to porous formation during cementing process.
    2.Applicable for high and ultra-high temperature oil well cementing.
    3.Control fluid loss in normal density cement slurries, lightweight and high density cement slurries.
    4.Compatible well with other additives, especially high temperature polymeric retarder.
    5.Used below temperature of 204.4℃(400℉, BHCT).
    6.Applicable mixing water: from fresh water to salt-saturated water.
    7.Compatible well with other additives, especially high temperature polymeric retarder.
    8.AF870 series consists of L-type liquid, L-A type anti-freezing liquid, P-P type high purity powder, P-D type dry-mixed powder and P-T type dual-use powder.

    Specifications

    Type

    Appearance

    Density,g/cm3

    Water-Solubility

    AF870L

    Colorless or faint yellow liquid

    1.10±0.05

    Soluble

    AF870L-A

    Colorless or faint yellow liquid

    1.15±0.05

    Soluble

    Type

    Appearance

    Density,g/cm3

    Water-Solubility

    AF870P-P

    White or faint yellow powder

    0.80±0.20

    Soluble

    AF870P-D

    Grey powder

    1.00±0.10

    Partly soluble

    AF870P-T

    White or faint yellow powder

    1.00±0.10

    Soluble

    Recommended Dosage

    Type

    AF870L(-A)

    AF870P-P

    AF870P-D

    AF870P-T

    Dosage Range (BWOC)

    2.0-8.0%

    0.5-2.0%

    1.5-5.0%

    1.5-5.0%

    Cement Slurry Performance

    Item

    Test condition

    Technical Indicator

    Density of the cement slurry, g/cm3

    25℃, Atmospheric Pressure

    1.90±0.01

    Fluid loss, ml

    Fresh water system

    150℃, 6.9mPa

    ≤50

    18% salt water system

    120℃, 6.9mPa

    ≤150

    Thickening performance

    Initial consistency, Bc

    150℃/73min, 94.4mPa

    ≤30

    40-100 Bc thickening time, min

    ≤40

    Free fluid, %

    150℃, 20.7mPa

    ≤1.4

    24h compressive strength, mPa

    ≥14

    Standard Packaging and Storage

    1.The liquid type products should be used within 12 months after production. Packed in 25kg, 200L and 5 US gallon plastic barrels.
    2.P-P/D type powder products should be used within 24 months and P-T type powder product should be used within 18 months after production. Packed in 25kg bag.
    3.Customized packages are also available.
    4.Once expired, it shall be tested before use.

    Package

    25KG/BAG or as you request.

    Storage

    Store at a ventilated, dry place.

    Executive Standard

    International Standard.